Haes MZAOV 3 amp Two Zone AOV Control Panel - Extendable - MZAOV-1001
Haes TechnologiesHaes MZAOV 3 amp Two Zone AOV Control Panel - Extendable - MZAOV-1001
Haes MZAOV-1001 AOV Control Panel is a Multi Zone open protocol AOV/Smoke Ventilation 3 amp Control Panel (MZAOV-1001), two detection zone, (extendable to 4), Smoke Vent Control Panel with integral 3 amp power supply, designed to control 24vdc actuators or magnets.
The panel has battery backup capability and assures that actuators can be powered in the event of a mains failure.
Vent controls and indications are provided on the front of the control panel with a large graphical LCD display and integral control inputs to accept signals from remote contacts, smoke detectors and manual controls.
Optional support for Rain Sensor and PIR inputs for environmental control and trap injury protection, plus 0/10v inputs and outputs to allow control interfacing with BMS systems and positional control Act output.
The MZAOV control panel range has been developed to provide a comprehensive solution to smoke vent control scenarios.
Main Features • 3 amp integral PSU • Large graphical display • Space for up to 12Ah batteries • Easy to program • Up to 4 detection zones, Conventional and Twin-wire • Up to 4 external inputs from other detection systems, to activate • Up to 4 monitored Actuator outputs for controlling smoke vents • Switch inputs to control wide combination of vents • Fireman switch input to override all other inputs • All inputs and actuator outputs monitored for Short and Open Circuit • User switch inputs configurable as local fireman switches • Thermostat input - Ventilation mode. Vents openable in 10% steps • Actuators configurable for independent operation or linked together as per required by 12101-9 • Optional support for Rain sensor, PIR and BMS control • Staggered start of actuators to avoid the combined start-up currents from simultaneous actuator activations • Monitoring of unused inputs and outputs can be disabled
• Space for up to 12Ah batteries • 2 or 4 Monitored Detection Zones. EOL = 6K8 • Twin Wire Selectable in Panel (Enables AV devices to be connected to det cct) • On Board Relays 1 x Alarm, 1 x Fault, Volt Free Changeover, Max 3A • Fireman's Control Switch Input for Open/Close/Auto • 2 or 4 Vent Control Switch Inputs (Rocker Switch) • 2 or 4 Reversal Actuator Control Output (2.5A Total Max) can be configured as a maintained output for a magnetic door • Aux Output 2 or 4 Voltage free normally open relay contact, closing when the associated zone is activated, Max 3A • BMS connection 0/10v positional control input 10% steps, 0/10v positional data output (available on separate PCB) • False Alarm Management type A, B & C dependency mode, approved by LPCB
Cabinet
Back box = 375mmW x 345mmH x 110mmD • Lid = 382mmW x 354mmH x 25mmD • Max battery size = 2 x 12Ah, 12v, SLA