Product Description

AOV-3 - Haes Standard AOV Control Panel

A single zone open protocol AOV / Smoke Ventilation control panel designed to control 24vdc actuators or magnets. Typically used in staircase lobbies, corridors or smoke extract shafts. The panel has battery backup capability and assures that actuators can be powered in the event of mains failure. 3A, 5A & 10A PSU versions are available for controlling small, medium and larger loads. Vent controls and indications are provided on the front of the panel with integral control inputs to accept signals from remote contacts, smoke detectors, manual controls and emergency push buttons. The AOV control panel range has been developed to provide a comprehensive solution to all smoke vent control scenarios.

Main Features • 3, 5 or 10 Amp PSU/ battery charger • Space for up to 3.2Ah batteries (AOV-3) • Space for up to 12Ah batteries (AOV-5/10) • 1 Amp magnetic vent control output • 1 x 5A timed polarity reversal actuator control outputs (AOV-3) • 2 x 5A timed polarity reversal actuator control outputs (AOV-5/10) • Alarm relay change over contacts • Fault relay change over contacts (fail safe) • Trigger input (monitored) • Smoke detector input (conventional or Twin wire operation) • False alarm mode • Vent control switch inputs , Open / Close • Fireman’s control switch inputs for On/ Off, Auto setting. • Disable & test modes • Vent status indications & controls on front • 12v dc output (100ma) for PIR power

External Indications • Vent Open • Vent Closed • Trigger Status • Detector Status • Supply Healthy • General Fault • General Alarm • Disabled • Test Mode • Rain Sensor Status • PIR Status • PSU Fault • System Fault • Access Status

External Controls • Keyswitch or code entry ‘activate controls’ • Colour coded buttons for controls and programming • Button functions: ➢Open Vent ➢ Close Vent ➢ Reset ➢ Code entry keys 1, 2, 3, 4

DIL Switch Selectable Options • Invert magnetic vent output • Actuator power to continuous mode • Set smoke to Twin Wire mode • BMS 0/10v control

Programmable Options • Set access code • Input circuit options • Latching • Short circuit to activate • Detector removal monitoring • False alarm mode selection • Actuator time setting, 10 to 150 seconds • Disable battery monitoring

Cabinet

AOV-3 • Back box = 300mmW x 250mmH x 80mmD • Lid = 308mmW x 260mmH x 23mmD • Max battery size = 2 x 3.2Ah, 12v, SLA

AOV-5/10 • Back box = 450mmW x 300mmH x 110mmD • Lid = 460mmW x 310mmH x 25mmD • Max battery size = 2 x 12Ah, 12v, SLA